Human CCL2/MCP-1 ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 0.04ng/ml(50 μl);0.03ng/ml(10 μl)
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Assay type: Sandwich Elisa
  • Brand:
CAT.NO. : AEH0010
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
CCL2/JE/MCP-1, is a chemokine that binds the receptor CCR2 and induces the chemoattraction of mononuclear cells. It induces the activation of monocytes, NK cells, lymphocytes, and basophils. Additionally, CCL2 promotes Th2 polarization in CD4+ T cells, and CCL2-mediated recruitment of monocytes to sites of inflammation contributes to disease severity in atherosclerosis, multiple sclerosis, and allergic asthma. Endogenous proteolytic trimming of CCL2 at the N-terminus, including the N-terminal pyrrolidone carboxylic acid-modified glutamine, downregulates activity but not receptor binding.
Typical Data

ng/ml

O.D.

Average

Corrected

0

0.0145

0.0126

0.0136

 

0.07

0.0257

0.0239

0.0248

0.0113

0.21

0.054

0.046

0.05

0.0365

0.62

0.133

0.1408

0.1369

0.1234

1.85

0.3971

0.4072

0.4022

0.3886

5.56

1.1312

1.1397

1.1355

1.1219

16.67

2.516

2.541

2.5285

2.515

50

3.9669

3.9689

3.9679

3.9544

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(ng/ml)

1.1

5.2

15.4

0.9

5.1

15.2

Standard Deviation

0.1

0.3

0.9

8.4

24.1

60.7

Coefficient Of Variation(%)

6.1

5.4

5.8

6.3

4.8

5.4


Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) 
Spike Recovery
The spike recovery was evaluated by spiking 3 levels of human CCL2 into health human serum sample. The un-spiked serum was used as blank in this experiment. 
The recovery ranged from 152% to 176% with an overall mean recovery of 162%. 
Sample Values

Sample Matrix

Sample Evaluated

Range(ng/ml)

Detectable%

Mean of Detectable(ng/ml)

Serum

30

1.98-10.55

100

5.03


Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of human CCL2 in this assay. No medical histories were available for the donors. 
n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable. 
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.