Mouse IFN-beta ELISA Kit

Key features and details

  • Specification: 96 Test
  • Sensitivity: 7.69 pg/ml (10 μl)
  • Standard Curve Range: 46.88~3000 pg/ml
  • Standard Curve Gradient: 7 Points/3 Folds
  • Number of Incubations: 2
  • Sample Volume: 10 μl
  • Assay type: Sandwich Elisa
  • Operation Duration: 120min
  • Brand:
CAT.NO. : AEM0040
RMB Please choose
RMB Please choose
Size:
96T
Trail, Bulk size or Custom requests Please contact us
Product Details
Background
Interferon-beta (IFN-beta) is a cytokine that is produced by fibroblasts and pathogen-exposed dendritic cells, macrophages, and endothelial cells. It signals through the heterodimeric IFN-alpha/beta Receptor. IFN-beta-deficient mice show increased susceptibility to experimental autoimmune encephalomyelitis (EAE), a disease model of human multiple sclerosis (MS). Furthermore, IFN-beta has been shown to suppress the Th17 cell response in both MS and EAE and has commonly been used as a treatment for MS.
Typical Data

pg/ml

O.D.

Average

Corrected

0.00

0.0411

0.0365

0.0388

46.88

0.0665

0.0600

0.0633

0.0245

93.75

0.0945

0.0893

0.0919

0.0531

187.50

0.1543

0.1501

0.1522

0.1134

375.00

0.2848

0.2850

0.2849

0.2461

750.00

0.5898

0.5864

0.5881

0.5493

1500.00

1.3820

1.2790

1.3305

1.2917

3000.00

3.2720

3.2060

3.2390

3.2002

Precision

Intra-assay Precision

Inter-assay Precision

Sample Number

S1

S2

S3

S1

S2

S3

22

22

22

6

6

6

Average(pg/ml)

59.5

302.9

1001.7

73.4

302.3

911.3

Standard Deviation

4.2

22.4

56.9

5.7

14.5

52.5

Coefficient of Variation(%)

7.0

7.4

5.7

7.7

4.8

5.8


Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.

Spike Recovery
The spike recovery was evaluated by spiking 3 levels of mouse IFN beta into health mouse serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 82% to 106% with an overall mean recovery of 96%.
Sample Values

Sample Matrix

Sample Evaluated

Range (pg/ml)

Detectable (%)

Mean of Detectable (pg/ml)

Serum

30

n.d.-31.13

3.3

31.13


Serum/Plasma – Thirty samples from apparently healthy mice were evaluated in this assay. No medical histories were available for the donors. n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
New Products
Get in touch with AREX
Name:*
Tel/Phone:*
Company:*
Email:*
Inquiry:
Captcha*
Submitting your email information means that you are willing to receive email information from AREX regarding technology, applications, products, and events. By clicking on the 'unsubscribe' button in the email or by contacting info@arexbio.com You can unsubscribe at any time by sending an email. Regarding your data usage information, please refer to our privacy policy.
© AREX 2024. All Rights Reserved. | 浙ICP备2024113709号-3 Sitemap